Monthly Archives: September 2015

Inquiry For VA-SA100 Autoclave

Comment: Dear Sir/Madam,

I am interested in acquiring a quote for your VA-SA100 autoclave including shipment cost to Kingstown, St Vincent and the Grenadines.
Thanks much.

regards

VA-SA100 Autoclave

VA-SA100 Autoclave

Steam Sterilizer Autoclave Machine VA-SA100 autoclave  Instructions and Principle:
Automatic control over the processes of filling water, heating, sterilization, steam exhaust and dryness.
1. Fully stainless steel material.
2. Horizontal sliding door, self- bulge seal ring, operated easily.
3. Door safety lock system, the door is made of high performance heat insulation material.
4. Positive pressure pulse function exhaust cool air of chamber thoroughly and ensure the steam saturation.
5. Micro-computer control technique, touch-key, LCD display the menu.
6. Built-in water tank. Steam and water circulation system, no external water source, not exhaust steam outside, environment is clean and dryness.
7. Preheating control function.
8. With two stainless steel sterilizing baskets.

Vertical  Autocalve

Vertical Autocalve

VA-SA100 autoclave Safety Device:
1. Safe protection of water lacking
2. The program will be stopped if water level lower than the low limit.
3. The buzzer alarms when a cycle of operation is completed.
4. Over temperature&over pressure auto-protection.
5. Over current protector.
6. Door safety interlock: The door cannot be opened until there is no pressure in the chamber and power for heating cannot be switched on until the door is firmly closed.
7. Safety valve of auto release against over-pressure.

More information about VA-SA100 autoclave,please click link: http://www.autoclavesale.com/.

Inquiry: 30L Portable Autoclave

Comment: I would like to get the price of 1 item of the 30L size and shipping to Tunisia. Moreover i would like to have a picture from the inside, and how is this item heated by gas (LPG)? Is it possible to heat this on a normal stove is that what you mean ? 

YX-280B Portable Autoclave_Bluestone Autoclave

YX-280B Portable Autoclave_Bluestone Autoclave

YX-280B Portable sterilizer autoclave Features:
1. High quality SUS304 stainless steel 0Cr18Ni9Ti
2. Overpressure auto-discharging at 0.145-0.1650.145-0.165Mpa
3. The highest working temperature: 126’c-129’c
4. Dual scale numerical pressure gauge indicate temperature and pressure
5. Operating easy, security and reliable
6. Dual heating system of coal or gas and electric, it is can be used both in coal heating and electric heating.
7. Silicone seal
Safety protection: Over heat protection.

 

Inquiry for 50L Electric ,Movable Autoclave

Comment:can you quote me 150L autoclave ,movable ,electric please.  Thanks.

Vertical_Autoclave VA-FJ50

Vertical_Autoclave VA-FJ50

Features of Vertical Autoclave VA-FJ Pressure Steam Sterilizer:

1. Fully stainless steel structure.

2. Indicator light indicates working state.

3. Over temperature & over pressure auto-protection.

4. Double scale indication pressure gauge.

5. Safe protection of water lacking.

6. Automatically shut off with beep reminding after sterilization.

7. Easy to operate, safe and reliable.

8. With two stainless steel sterilizing baskets.

More information about 50L Electric ,Movable Vertical Autoclave VA-FJ50,Please refer to :http://www.autoclavesale.com/vertical-autoclave-va-fj-pressure-steam-sterilizer-bluestone-ltd.html

 

How to Use an Autoclave

An autoclave is the most effective way of sterilizing medical and scientific equipment. While simple boiling in water at normal pressure kills most microbes and spores, it won’t kill them all. An autoclave pressurizes the water to 1 atmosphere or 15 pounds per square inch, which in turn raises the water’s boiling point. The autoclave then heats the water until boiling its new, elevated boiling temperature, at which point it is hot enough to kill all forms of life and thus sterilize the apparatus or equipment inside within 15 minutes.

Horizontal Cylindrical Autoclave

Horizontal Cylindrical Autoclave For Sale

Instructions

  1. Twist the control knob for the drain valve on the autoclave, usually located on the bottom front of the machine, to the closed position.
  2. Open the door on the autoclave and add hot water in the bottom of this opening, filling it to just below the front reservoir lip. On most machines this will take about 1 gallon of water.
  3. Load the material to be sterilized into the shelf in the autoclave. Liquids in bottles should be 3/4 or less full, with lids slightly loosened. Clean petri dishes should be loaded in top side up, contaminated petri dishes get loaded agar side down, and instruments should be rolled in brown paper, which is then stapled to secure it.
  4. Close the door of the autoclave and press down on the long handle to latch it securely.
  5. Toggle the exhaust switch, located at the top middle of most machines, to slow exhaust if you are sterilizing materials that contain water, or fast exhaust for sterilizing apparatus.
  6. Twist the timer to select the appropriate length of sterilization time. For small-volume machines this is 15 minutes, for machines containing over 1 liter of volume this is 30 minutes, and for larger machines with 1 gallon or more of volume you should select a 60 minute cycle. This starts the machine.
  7. Wait until the timer and pressure indicator both read zero, and then open the door, taking care to keep your hands, arms and face away from the upper parts of the door where steam is emerging and might burn you.
  8. Remove sterilized items using sterile, heat-proof gloves. Pour any melted contaminated agar away immediately into a biohazard container, then rinse glassware with hot water.
  9. Twist the drain valve control on the autoclave to the open position to empty the water.

 

Horizontal_Autoclave

Loading chamber_Horizontal Autoclave HA-BC

More information about autoclave,please refer to :http://www.autoclavesale.com/

What Is the Autoclave Sterilization Process?

Typical Cycle

During the autoclave process, the chamber is loaded with medical instruments. The technician checks the load to make sure it is properly distributed for maximum steam penetration. Chemical and biological indicators may be added to validate the effectiveness of the cycle. The door is then closed and sealed. The user selects a pre-existing cycle or programs new parameters using the touch screen. If the sterilizer has a safety-locking mechanism, this is automatically engaged as soon as the cycle begins. It will not release until the load has finished processing and cooled to a safe temperature.

Autocalve

Autocalve

A vacuum pump removes the air from the chamber. Heated steam is introduced into the autoclave via an external pipeline or from a steam generator that is integrated in the sterilizer. The pressure inside the autoclave is increased, and the temperature quickly begins to rise. When the steam reaches 121 degrees Celsius, this temperature is maintained for 15 minutes.

The steam is then removed from the chamber and heated air is used to dry the load. For wrapped instruments, a post-vacuum cycle may be required to aid in the drying process. Next, pressure is normalized and the load is allowed to cool. The chemical indicator can be checked immediately to verify that the appropriate temperature was reached during the cycle. The biological indicator must be cultured to see if any microbes remain alive. Many autoclaves have microprocessors and a data storage unit that can display and/or archive the information for each cycle.

sterilizers VA-FJ

Vertical_Autoclave

Troubleshooting

Wet loads are a common problem in many sterile processing departments. If moisture is detected in a load at the end of a cycle, it is not considered sterile, and it must be reprocessed. Technicians can reduce the frequency of these wet loads by using proper loading and wrapping techniques. If a tray of hot instruments is removed from the autoclave too soon, moisture from the air (contaminated with germs) immediately begins to form as condensation on the exposed surfaces. Ensuring that the drying and cool-down portions of the cycle are not cut short can prevent this problem.

Autoclaves

Horizontal_Autoclave

More information about autoclave,please refer to :http://www.autoclavesale.com/