Double Door Autoclave Supplier Bluestone Medical

Sir,
We are from Bangladesh.  We need Double Door Autoclave for our customers.

So, please send your machine specification in details as soon as possible.

Thanks

Double Door Autoclave

Double Door Autoclave

Double Door Autoclave Exporter and Supplier- Bluestone Medical

Double Door Autoclave can be used in agriculture, mushroom cultivating, hospitals, pubic healty centers, health stations, clinics, scientific resarh institutes, university and food sterilization, etc.

Safety Protection:

1. Heater protection;
2. Anti-dry heating;
3. Safety interlock door;
4. Over-temperature protection;
5. Over-pressure protection;
6. Automatic release safety valve;
7. Electric safety protective device.

Instructions and Principle of Double Door Autoclave – Bluestone Medical

The main body is with horizontal rectangle double layer structure, the inside chamber is made of SUS30408 or SUS31608 stainless steel, the outer layer is made of the brushed decorative sheet, and the there is motorized door or sliding door for choose, pneumatic sealing, and the double door interlocking are strictly in accordance with the GSSD required.

The control system: Adopt the Siemens PLC and Siemens touch screen.
The piping system: Adopt with the reliable Germany Burket or GEMU pneumatic angle type valve, water ring pump and 0.22µm high efficiency sterile medical grade filters, the pipe clamp adopts the quick connectors, the piping and the related spares are all according to the sanitation standard.

Autoclave

Double Door Autoclave

1. With Germany Simens PLC platform independent research and development, human-Machine Interaction, convenient for operation.
2. Software design and manufacture products in strict accordance with the technical requirements for the sterilization process.
3. The Operating authority is divided into three levels to the manager, the technologist, and the operators.
4. Program interlocked, by the program is running, the sealing door can not be open.
5. All the alarm and the technical figures can be recorded and print.
6. If the inner chamber is higher than the safety pressure, the door can not be open.
7. Perfect product safety protection measures, 4 level emergency treatment of abnormal state.

Sterilization Objects: Unwrapped or Wrapped instruments, Sugircal instruments, Glassware, Liquid , Culture Media, Rubber Material, Gowns, Dressing, Gloves, etc.

After-sale Service: 1 year quality guarantee; Question responsed within 24 hours; Video or photos instruction guide.

Double Door Autoclave Specifiction Datas:

MODEL HA-BVD250  HA-BVD360 HA-BVD600 HA-BVD800 HA-BVD1200 HA-BVD1500 HA-BVD2000
 Capacity(L)  250Liters  360Liters  600Liters  800Liters 1200Liters  1500Liters  2000Liters
 Inner Chamber Dimension
(L*W*H mm)
 800*600*600  1000*600*600  1200*610*910  1500*610*910  1500*680*1180  1900*680*1180  1700*1000*1200
 Outer Dimension
(L*W*H mm)
 1100*1300*1700  1300*1300*1700  1500*1350*1950  1800*1350*1950  1790*1450*1950  2150*1450*1950  1950*1850*2000
 Steam Pressuer
and the Consumption
 0.4-0.8Mpa
15KG
 0.4-0.8Mpa
20KG
 0.4-0.8Mpa
30KG
 0.4-0.8Mpa
40KG
 0.4-0.8Mpa
48KG
 0.4-0.8Mpa
55KG
 0.4-0.8Mpa
65KG
 Water Source Pressure
and the Consumption
 0.15-0.3Mpa
35KG
 0.15-0.3Mpa
40KG
 0.15-0.3Mpa
45KG
 0.15-0.3Mpa
50KG
 0.15-0.3Mpa
55KG
 0.15-0.3Mpa
60KG
 0.15-0.3Mpa
65KG
 Power  2-2.4KW  2-2.4KW  3-3.6KW  3KW  4KW  4KW  4.5KW
 Net Weight(KG)  900  1000  1400 1600  1800  2000  2500
 Design Pressure  0.245Mpa  0.245Mpa  0.245Mpa  0.245Mpa  0.245Mpa  0.245Mpa  0.245Mpa
 Design Temperature  139ºC  139ºC  139ºC  139ºC  139ºC  139ºC  139ºC