Category Archives: News about Autoclave Sterilizer

News about Autoclave Sterilizer

Inquiry Of Vertical Pulse Vacuum Autoclave VA-SVN50

Comment: Can you quote the best price for Pulse Vacuum Autoclave VA-SVN50? Thanks.

Pulse Vacuum Autoclave_VA-SVN

Pulse Vacuum Autoclave_VA-SVN

Pulse Vacuum Autoclave VA-SVN50  Features:

1. Automatically controlled by computer, digital display of working status, touch type key.

2. Dynamically showed the temperature, pressure time and vacuum rate, and the full cycle.

3. Fully automatically route for water inlet, pulse vacuum, heating, sterilizing, draining, exhausting, vacuum drying.

4. 3 times pulse vacuum, which make the vacuum rate as -0.081 Mpa, and ensure the high extracting of inner air from dressing, A, B type hollowed appliance.

5. With 4 fixed program for appliance, medical dressing, rubbers and fluid, and the user can also set the program as they need.

6. Equipped with the PT/TT testing connector, easy to run the testing.

7. Multiple pulse vacuum drying after sterilizing, ensure the nice sterilizing.

8. Equipped with 0.22 µm bacteria filter, ensure the sterile air enter the inner vacuum environment, avoid the second contamination.

9. Hand wheel type of quick-open door structure, self-inflating type seal.

10. Adopted with immersed heating, with high heating efficiency.

11. Steam-water inner circulation system: no steam discharge, and the environment for sterilizing will be clean and dry.

12. Automatically shut off with beep reminding after sterilization.

13. Fully high quality stainless, Pulse Vacuum Autoclave equipped with double stainless steel baskets.

More information about pluse vacuum autoclave please refer to :http://www.autoclavesale.com/

Inquiry for VA-SD100 Vertical Autoclave

Dear Sir / Madam,

Good day sir/ madam,

Introduce, Iam from Indonesia, we need inquiry to you of your product vertical autoclave VA-SD100 qty 1 unit, could you please to us provide the best price.
We are waiting your reply to soonest.
Thank you very much for your great help.
Warm Regards,
Vertical Autoclave VA-SD100

Vertical Autoclave VA-SD100

China Digital Vertical Autoclave VA-SD Top Loading Autoclave – Bluestone Autoclave, View China Digital Autoclave , Bluestone Autoclave Product Details from Anhui Sada Trading Co., Ltd. on Alibaba.com

Main features of VA-SD Vertical Autoclave

1. Fully stainless steel stricture.

2. Hand wheel type of quick-open door structure.

3. Door safety lock system.

4. Digital display of working status, touch type key.

5. Auto discharge the cool air, and steam discharging automatically after sterilizing.

6. Over temperature and over pressure auto-protection.

7. Safe protection of water lacking.

8. Self-inflating type seal.

9. Automatically shut off with beep reminding after sterilization.

10. With two stainless steel sterilizing baskets.

11. Install drying system according request.

Vertical_Autoclave

Vertical_Autoclave                                                               

 More information about vertical autoclave,please refer to : http://www.autoclavesale.com/

Inquiry about Single door vacuum autoclave steam sterilizer_Bluestone Autoclave

Dear Sir,

We are Nepal based sales and service***company.

We are in urgent need for Autoclave for waste sterilization and the HA-BVS360 manufactured by your company fits to our choice.

So, can you please send the quotation for the same.

Model: HA-BVS360

Volume range: 250-3000 liters

large autoclave

HA-BVS Vacuum Horizontal Autoclave_Bluetone Autoclave

Feature of HA-BVS Horizontal Vacuum Autoclave:

The main body is with horizontal rectangle double layer structure, the inside chamber is made of SUS30408 or SUS31608 stainless steel, the outer layer is made of the brushed decorative sheet, and the there is motorized door or sliding door for choose, pneumatic sealing, and the double door interlocking are strictly in accordance with the GSSD required.

The control system: Adopt the Siemens PLC and Siemens touch screen.

The piping system: Adopt with the reliable Germany Burket or GEMU pneumatic angle type valve, water ring pump and 0.22µm high efficiency sterile medical grade filters, the pipe clamp adopts the quick connectors, the piping and the related spares are all according to the sanitation standard.

1. With Germany Simens PLC platform independent research and development, human-Machine Interaction, convenient for operation.

2. Software design and manufacture products in strict accordance with the technical requirements for the sterilization process.

3. The Operating authority is divided into three levels to the manager, the technologist, and the operators.

4. Program interlocked, by the program is running, the sealing door can not be open.

5. All the alarm and the technical figures can be recorded and print.

6. If the inner chamber is higher than the safety pressure, the door can not be open.

7. Perfect product safety protection measures, 4 level emergency treatment of abnormal state.

More product information, pls visit our website: http://www.autoclavesale.com

large autoclave

Double Door Vacuum Autolcave_Front view

Horizontal_Autoclave_HA-BVD_back_2

Double Door Vacuum Autoclave_Back review

 

Medical equipment inquiry: Hospital steam sterilizer autoclave

Comments: We are medical equipment importer in Iran and number of our important customer requested for Waste manager systems and Hospital steam Autoclaves.
So we are interested to know more about your products and price
HA-BA200_5

Horizontal hospital Autoclave HA-BA200_BLuestone Autoclave

Model: HA-BC

Available volume: 150/200/280 liters

Main features of horizontal hospital autoclave

1. Horizontal Cylindrical Pressure Steam Sterilizer Type.

2. Sterilizing course automatic sterilization controlled.

3. With drying function.

4. With over-temperature, over-pressure auto-protect device.

5. The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027 Mpa. It can’t be start on if the door doesn’t close well.

6. The safety valve will be open automatically when the inner pressure over 0.24 MPa and the steam be exhausting to the water link.

7. Lacking Water Protection.

8. Built-in Printer.

9. Outside frame material is high quality carbon steel, Inside chamber material is stainless steel SUS304.

More product information, pls visit our website: http://www.autoclavesale.com/

Inquiry For Autoclaves 75L With Built-In Printer

Comment:
   Hi
  Please  send  us  dealer price list for autoclaves 75L with built-in printer.
  Best regards,
Vertical Pressure Steam Sterilizer VA-SV for sale – Sada Ltd
 Steam Sterilizer VA-SV75

Steam Sterilizer VA-SV75

Model: VA-SV50, VA-SV75
Available Volume: 50 liters, 75 liters
Vertical Pressure Steam Sterilizer VA-SV75 Instructions and Principle:
1. Automatically controlled by computer, digital display of working status, touch type key.
2. Dynamically showed the temperature, pressure time and vacuum rate, and the full cycle.
3. Fully automatically route for water inlet, pulse vacuum, heating, sterilizing, draining, exhausting, vacuum drying.
4. 3 times pulse vacuum, which make the vacuum rate as -0.081 Mpa, and ensure the high extracting of inner air from dressing, A, B type hollowed appliance.
5. With 4 fixed program for appliance, medical dressing, rubbers and fluid, and the user can also set the program as they need.
6. Equipped with the PT/TT testing connector, easy to run the testing.
7. Multiple pulse vacuum drying after sterilizing, ensure the nice sterilizing.
8. Equipped with 0.22 µm bacteria filter, ensure the sterile air enter the inner vacuum environment, avoid the second contamination.
9. Hand wheel type of quick-open door structure, self-inflating type seal.
10. Adopted with immersed heating, with high heating efficiency.
11. Steam-water inner circulation system: no steam discharge, and the environment for sterilizing will be clean and dry.
12. Automatically shut off with beep reminding after sterilization.
13. Fully high quality stainless, equipped with double stainless steel baskets.

 Steam Sterilizer VA-SV75

Steam Sterilizer VA-SV75

 More information about steam sterilizer VA-SV75,Please refer to:http://www.autoclavesale.com/

Inquiry For Cheapest 35L Vertical Autoclave.

Comment: How much is your cheapest 35L vertical autoclave.

Regards

Vertical Autoclave VA-FJ Pressure Steam Sterilizer – Sada Ltd.

autlcalve

Vertical Autoclave VA-FJ-Bluestone Autoclave

Features of Vertical Autoclave VA-FJ Pressure Steam Sterilizer:

1. Fully stainless steel structure.

2. Indicator light indicates working state.

3. Over temperature & over pressure auto-protection.

4. Double scale indication pressure gauge.

5. Safe protection of water lacking.

6. Automatically shut off with beep reminding after sterilization.

7. Easy to operate, safe and reliable.

8. With two stainless steel sterilizing baskets.

sterilizers VA-FJ

Vertical_Autoclave VA-FJ35

More Information About Vertical Autoclave VA-FJ35,Please refer to: http://www.autoclavesale.com/

Who invented autoclaves?

Horizontal Cylindrical Autoclave

Horizontal Cylindrical Autoclave For Sale

1. Ancient Greeks use boiling water to sterilize medical tools.

2. 1679: French engineer Denis Papin (1647–1712) invents the steam pressure cooker—an important step in the development of steam engines.

3. 1860s: French biologist Louis Pasteur (1822–1895) helps to confirm the germ theory of disease. He realizes that heating things to kill germs can prevent diseases and extend the life of foodstuffs (which leads him to the invention of pasteurization).

4. 1880s: Pasteur’s collaborator Charles Chamberland (1851–1908) invents the modern autoclave.

autlcalve

Vertical Autoclave VA-FJ-Bluestone Autoclave

 

Importance of Autoclave

The increasing concern for health, safety and hygiene necessitated the invention of various means of sterilization. One significant means of sterilization is the autoclave, which is used for sterilizing all kinds of medical and laboratory instruments prior to use. It is also used for rendering all biohazardous substances and infectious wastes sterile before disposal.

Portable Steam Autoclave_Bluestone Autoclave

Portable Steam Autoclave_Bluestone Autoclave

What Is an Autoclave?

  • The autoclave was invented by Charles Chamberland in 1879. It is designed on the principle of a pressure cooker, using supersaturated steam under pressure for sterilization. The body of an autoclave is made of steel. It can withstand great pressure and a high temperature. A simple autoclave is provided with a vent to allow the inside air to escape while the chamber gets filled with superheated steam. It is also provided with a thermometer and pressure gauge to monitor the temperature and pressure inside the autoclave chamber. However, more technically advanced versions of steam autoclaves are also provided with vacuum pumps. Like our model TS-DDV Bench Top Autoclave.
  • TS-DDV50_1

    Table Top Vacuum Autoclave TS-DDV_Bluestone Autoclave

Operating Principle

  • An autoclave uses steam under pressure as a sterilizing agent to kill microorganisms. When the autoclave is packed and ready, it is switched on. As the water inside the autoclave chamber starts to boil, steam begins to fill up the chamber. As more and more steam is generated, it causes the air inside the chamber to evacuate from the vent. Eventually the entire autoclave chamber is filled with supersaturated steam. Steam under pressure attains much higher temperature than under normal conditions, and this increases its sterilizing ability and its penetration power.

Standard Operational Settings

  • The time that is required to kill a particular amount of microbial population is known as the thermal death time (TDT). Greater temperature reduces the TDT, while lower temperature in the autoclave chamber increases the TDT. Usually, a shorter TDT is preferred, which means that the temperature attained must be very high. However, the TDT increases for larger loads of materials that need sterilization. Hence TDT depends on temperature, pressure as well as the load amount. Usually 121ºC and 15 PSI pressure is employed. But if the loads are lesser, 115ºC and 10 PSI pressure are required. If the loads are higher, 132ºC and 27 PSI pressure are often necessary.

Effectiveness

  • The supersaturated steam used for sterilization in an autoclave ensures quicker heating and deeper penetration of steam. It kills microorganisms due to coagulation of vital proteins and enzymes in its body. It is capable of killing all forms of microorganisms, including protozoa, bacteria, fungi, algae and even viruses. Moist heat can even penetrate the microbial spores that are resistant against all other forms of sterilizing agents and kill them.

Uses

  • An autoclave is used in hospitals to sterilize surgical instruments, dressings and also before discarding toxic or infectious medical wastes. Tattoo parlors and skin-piercing clinics also use an autoclave to prevent spreading infections through needles used for piercing. An autoclave is also used in the manufacture of dyes.
  • More information about autoclaves, pls visit our website: http://www.autoclavesale.com/



How to Autoclave Pipette Tips shared by autoclavesale.com

Table Top Autoclave is used to sterilize items, such as pipette tips. The process achieves sterilization by removing air which causes steam to become superheated. It removes air in one of two ways: evacuation pump or downward steam displacement. Sterilization plays a vital role in research and any scientific endeavor using pipette tips

Table Top Autoclave_Bluestone Autoclave

Table Top Autoclave_Bluestone Autoclave

Buying Tips

  • When purchasing pipette tips, ensure that they can be autoclaved. Not all tips can. If you autoclave tips that should not be autoclaved, it can cause a huge mess and even damage the autoclave.

Time

  • The amount of time needed for an autoclave cycle does not refer to the entire cycle time but the entire steam penetration time: the time needed for the entire autoclave load to reach the set temperature and the hold time at this set temperature. Ensure that you set the correct cycle time for the sterilization; if you just go by the entire cycle time, then you won’t sterilize your tips.

Indicators

  • Autoclave tape will indicate when it reaches a temperature of above 80 degrees Celsius. It does not specify that the correct time at this temperature was met. Besides autoclave tape, ensure that the autoclave works by using biological indicators or chemical indicators. These other indicators measure both temperature and time at that temperature.

Remove Items

  • Never open the autoclave unless the pressure reads zero. Wear thermal gloves when removing the pipette tips since they will be hot.

Tip Boxes

  • Refill old pipette tip boxes to autoclave new pipette tips. This not only makes loading the autoclave easy but you can use the tips directly from the box after autoclaving. Otherwise, you must place the tips in a glass beaker and cover them with aluminum foil.

Secondary Container

  • Always place the pipette tips in a secondary container. Stack the pipette tip boxes in one large container. This makes loading and unloading the table top autoclaver easier and will protect the tips again any accidents or spills within the autoclave.
Table Top Autoclave_Bluestone Autoclave

Table Top Autoclave_Bluestone Autoclave

More product information, pls visit our website: http://www.autoclavesale.com

Inqiury For Good Dental Autoclave TS-DDV Pulsating Vacuum Desktop Steam Sterilizer With Mini Printer LCD Display

Subject: Quotation

We need with very urgent Price and delivery time for 50 units of the
reference Pulsating Vacuum Desktop Steam Sterilizer TS-DDV12, I send you the technical characteristics that the
equipment must have , I need that you can write in red color the
characteristics that the equipment don´t have.
I need also a cataloque in English of this equipment.

Best regards,

Pulsating Vacuum Desktop Steam Sterilizer

Pulsating Vacuum Desktop Steam Sterilizer

Good dental autoclave TS-DDV pulsating vacuum desktop steam sterilizer TS-DDV with mini printer LCD display, View good vacuume autoclave, Bluestone Autoclave Product Details from Anhui Sada Trading Co., Ltd. on Alibaba.com

Steam Sterilizer TS-DDV Characteristics:

1. Standard Class B with three times vacuum and drying, the remaining temperature

of sterilized instrument is less than 0.2%.

2. LCD display working status, touch keys.

3. The vacuum data can reach -0.8bar, it fits various instrument, including package,

unpackaged, solid, hollow,multi-apertures and inset pipes. It makes sure the

instrument can be sterilized completely.

4. Fully computer controlled LCD display bright show. The interface is modularized panel for

easy operation.

5. It is installed with BOWIE&DICK which measures the penetration of water steam.

6. It has vacuum text which can make sure the ability of texting vacuuming.

7. Fast and independent steam generator.

8. Built-in mini printer which can record the steam sterilizer TS-DDV information.

9. Safety valve,Safety lock door system,Pressure or temperature overload protection,

Alarm system.

10. Can inactivate HIV, HBV, mad cow virus and bacillus.

 steam sterilizer TS-DDV

     steam sterilizer TS-DDV

 

 steam sterilizer TS-DDV

steam sterilizer TS-DDV

More information about steam sterilizer TS-DDV,Please visit our company website:http://www.autoclavesale.com/