Inquiry: 30L Portable Autoclave

Comment: I would like to get the price of 1 item of the 30L size and shipping to Tunisia. Moreover i would like to have a picture from the inside, and how is this item heated by gas (LPG)? Is it possible to heat this on a normal stove is that what you mean ? 

YX-280B Portable Autoclave_Bluestone Autoclave

YX-280B Portable Autoclave_Bluestone Autoclave

YX-280B Portable sterilizer autoclave Features:
1. High quality SUS304 stainless steel 0Cr18Ni9Ti
2. Overpressure auto-discharging at 0.145-0.1650.145-0.165Mpa
3. The highest working temperature: 126’c-129’c
4. Dual scale numerical pressure gauge indicate temperature and pressure
5. Operating easy, security and reliable
6. Dual heating system of coal or gas and electric, it is can be used both in coal heating and electric heating.
7. Silicone seal
Safety protection: Over heat protection.

 

Inquiry for 50L Electric ,Movable Autoclave

Comment:can you quote me 150L autoclave ,movable ,electric please.  Thanks.

Vertical_Autoclave VA-FJ50

Vertical_Autoclave VA-FJ50

Features of Vertical Autoclave VA-FJ Pressure Steam Sterilizer:

1. Fully stainless steel structure.

2. Indicator light indicates working state.

3. Over temperature & over pressure auto-protection.

4. Double scale indication pressure gauge.

5. Safe protection of water lacking.

6. Automatically shut off with beep reminding after sterilization.

7. Easy to operate, safe and reliable.

8. With two stainless steel sterilizing baskets.

More information about 50L Electric ,Movable Vertical Autoclave VA-FJ50,Please refer to :http://www.autoclavesale.com/vertical-autoclave-va-fj-pressure-steam-sterilizer-bluestone-ltd.html

 

How to Use an Autoclave

An autoclave is the most effective way of sterilizing medical and scientific equipment. While simple boiling in water at normal pressure kills most microbes and spores, it won’t kill them all. An autoclave pressurizes the water to 1 atmosphere or 15 pounds per square inch, which in turn raises the water’s boiling point. The autoclave then heats the water until boiling its new, elevated boiling temperature, at which point it is hot enough to kill all forms of life and thus sterilize the apparatus or equipment inside within 15 minutes.

Horizontal Cylindrical Autoclave

Horizontal Cylindrical Autoclave For Sale

Instructions

  1. Twist the control knob for the drain valve on the autoclave, usually located on the bottom front of the machine, to the closed position.
  2. Open the door on the autoclave and add hot water in the bottom of this opening, filling it to just below the front reservoir lip. On most machines this will take about 1 gallon of water.
  3. Load the material to be sterilized into the shelf in the autoclave. Liquids in bottles should be 3/4 or less full, with lids slightly loosened. Clean petri dishes should be loaded in top side up, contaminated petri dishes get loaded agar side down, and instruments should be rolled in brown paper, which is then stapled to secure it.
  4. Close the door of the autoclave and press down on the long handle to latch it securely.
  5. Toggle the exhaust switch, located at the top middle of most machines, to slow exhaust if you are sterilizing materials that contain water, or fast exhaust for sterilizing apparatus.
  6. Twist the timer to select the appropriate length of sterilization time. For small-volume machines this is 15 minutes, for machines containing over 1 liter of volume this is 30 minutes, and for larger machines with 1 gallon or more of volume you should select a 60 minute cycle. This starts the machine.
  7. Wait until the timer and pressure indicator both read zero, and then open the door, taking care to keep your hands, arms and face away from the upper parts of the door where steam is emerging and might burn you.
  8. Remove sterilized items using sterile, heat-proof gloves. Pour any melted contaminated agar away immediately into a biohazard container, then rinse glassware with hot water.
  9. Twist the drain valve control on the autoclave to the open position to empty the water.

 

Horizontal_Autoclave

Loading chamber_Horizontal Autoclave HA-BC

More information about autoclave,please refer to :http://www.autoclavesale.com/

What Is the Autoclave Sterilization Process?

Typical Cycle

During the autoclave process, the chamber is loaded with medical instruments. The technician checks the load to make sure it is properly distributed for maximum steam penetration. Chemical and biological indicators may be added to validate the effectiveness of the cycle. The door is then closed and sealed. The user selects a pre-existing cycle or programs new parameters using the touch screen. If the sterilizer has a safety-locking mechanism, this is automatically engaged as soon as the cycle begins. It will not release until the load has finished processing and cooled to a safe temperature.

Autocalve

Autocalve

A vacuum pump removes the air from the chamber. Heated steam is introduced into the autoclave via an external pipeline or from a steam generator that is integrated in the sterilizer. The pressure inside the autoclave is increased, and the temperature quickly begins to rise. When the steam reaches 121 degrees Celsius, this temperature is maintained for 15 minutes.

The steam is then removed from the chamber and heated air is used to dry the load. For wrapped instruments, a post-vacuum cycle may be required to aid in the drying process. Next, pressure is normalized and the load is allowed to cool. The chemical indicator can be checked immediately to verify that the appropriate temperature was reached during the cycle. The biological indicator must be cultured to see if any microbes remain alive. Many autoclaves have microprocessors and a data storage unit that can display and/or archive the information for each cycle.

sterilizers VA-FJ

Vertical_Autoclave

Troubleshooting

Wet loads are a common problem in many sterile processing departments. If moisture is detected in a load at the end of a cycle, it is not considered sterile, and it must be reprocessed. Technicians can reduce the frequency of these wet loads by using proper loading and wrapping techniques. If a tray of hot instruments is removed from the autoclave too soon, moisture from the air (contaminated with germs) immediately begins to form as condensation on the exposed surfaces. Ensuring that the drying and cool-down portions of the cycle are not cut short can prevent this problem.

Autoclaves

Horizontal_Autoclave

More information about autoclave,please refer to :http://www.autoclavesale.com/

Types of Autoclaves

An autoclave is a device that is used to sterilize medical, beautician and other equipment such as tattooing and piercing paraphernalia. The basic function of the machine is to kill bacteria. This is done through application of extreme heat, steam and pressure to the articles placed in the sterilization chamber. This is accomplished by the removal of air from the sterilization chamber to create a vacuum, then superheated steam is applied. There are several types of autoclave in use.

Vertical_Autoclave_VA-SD50

Vertical_Autoclave_VA-SD50

Downward Displacement

  • The downward displacement autoclave is also referred to as a gravity displacement unit. This is because of the method of air removal in the sterilization chamber. A heating element is submerged in a pool of water, which, when heated, becomes steam. As steam is lighter than air, it forces the air in the sterilization chamber downward and out through a drain hole. Once the temperature in the sterilization chamber is sufficient, the drain hole is closed automatically and the sterilization process begins.

Positive Pressure Displacement

  • A positive pressure displacement autoclave is an improvement upon the design of a downward displacement unit. Steam is created in a second, separate chamber and held until the proper amount to displace all of the air in the sterilization chamber is accumulated. The steam is then released into the sterilization chamber in a pressurized blast, forcing the air out through the drain hole and starting the sterilization process. This has the effect of a more accurate displacement of air than a downward displacement unit can achieve.

Negative Pressure Displacement

  • A negative pressure displacement autoclave is one of the most accurate types of unit available. Once the sterilization chamber door is closed, a vacuum pump removes the air. Steam is created in a second, separate chamber. Once the air has been completely removed from the sterilization chamber, the steam is then released into the sterilization chamber in a pressurized blast much like that of a positive pressure displacement unit. The negative pressure displacement unit is able to achieve a high “Sterility Assurance Level” (SAL), but the system can be quite large and costly.

Autoclaves

Triple Vacuum Autoclave

  • A triple vacuum autoclave is set up in a similar fashion to a negative pressure displacement unit in that there is a vacuum pump to remove air from the sterilization chamber and steam is created in a second, separate chamber or unit. The process begins by the vacuum removing the air, then a pulse of steam. This is repeated three times, hence the name “triple vacuum” autoclave. This type of autoclave is suitable for all types of instruments and is very versatile.

Type “N” vs. Type “B”

  • Each autoclave can be classified as a type “N” unit or a type “B” unit. Type “N” units do not use a vacuum to remove air from the sterilization chamber, whereas type “B” units do use a vacuum pump. The difference in operation means type “N” autoclaves are suitable for a specific type of load–for solid, unwrapped instruments. Type “B” autoclaves can be used on wrapped and hollow instruments, which means a piece of equipment can be sterilized now for use later.
Class B Tabel Top Autoclave

Class B Tabel Top Autoclave_Bluestone Autoclave

More information about autoclave,please refer to :http://www.autoclavesale.com/

Steam Sterilizer Autoclave Machine, Sliding Door, Digital Display and Automatic Autoclave VA-SA100

Comment: Dear Sir/Madam,

I am interested in acquiring a quote for your VA-SA100 including shipment cost to Kingstown, St Vincent and the Grenadines.

Thanks much.
regards

Vertical_Autoclave_VA-SA

Vertical_Autoclave_VA-SA

Steam Sterilizer Autoclave Machine, Sliding Door, Digital Display and Automatic Autoclave VA-SA100 Instructions and Principle:

Automatic control over the processes of filling water, heating, sterilization, steam exhaust and dryness.
1. Fully stainless steel material Automatic Autoclave.
2. Horizontal sliding door, self- bulge seal ring, operated easily.
3. Door safety lock system, the door is made of high performance heat insulation material.
4. Positive pressure pulse function exhaust cool air of chamber thoroughly and ensure the steam saturation.
5. Micro-computer control technique, touch-key, LCD display the menu.
6. Built-in water tank. Steam and water circulation system, no external water source, not exhaust steam outside, environment is clean and dryness.
7. Preheating control function.
8. Automatic Autoclave With two stainless steel sterilizing baskets.

Verticlave Autoclave

Verticlave Autoclave

Safety Device:

1. Safe protection of water lacking
2. The program will be stopped if water level lower than the low limit.
3. The buzzer alarms when a cycle of operation is completed.
4. Over temperature&over pressure auto-protection.
5. Over current protector.
6. Door safety interlock: The door cannot be opened until there is no pressure in the chamber and power for heating cannot be switched on until the door is firmly closed.
7. Safety valve of auto release against over-pressure.

More information about Automatic Autoclave ,please refer to :http://www.autoclavesale.com/steam-sterilizer-autoclave-machine-sliding-door-digital-display-and-automatic-autoclave-bluestone-ltd.html

Pulsating Vacuum Desktop Steam Sterilizer TS-DDV

Comment: Pulsating Vacuum Desktop Steam Sterilizer, LCD display and built-in mini printer -Bluestone Ltd.

Model:  TS-DDC20, TS-DDV24, TS-DDV35, TS-DDV50

what are your prices for these units. looking to buy one of them.

TS-DDV Class B Autoclave

TS-DDV Class B Autoclave

Pulsating Vacuum Desktop Steam Sterilizer, LCD display and built-in mini printer Instructions and Principle:

1. Standard Class B with three times vacuum and drying, the remaining humidity of sterilized instrument is less than 0.2%.
2. LCD display working status, touch keys.
3. The vacuum data can reach -0.8bar, it fits various instrument, including package, unpackaged, solid, hollow,multi-apertures and inset pipes. It makes sure the instrument can be sterilized completely.
4. Fully computer controlled LCD display bright show. The interface is modularized panel for easy operation.
5. It is installed with BOWIE&DICK which measures the penetration of water steam.
6. It has vacuum text which can make sure the ability of texting vacuuming.
7. Fast and independent steam generator.
8. Built-in mini printer which can record the sterilizer information.
9. Safety valve, Safety lock door system, Pressure or temperature overload protection, Alarm system.
10. Can inactivate HIV, HBV, mad cow virus and bacillus.

Pulsating Vacuum Desktop Steam Sterilizer TS-DDV35/TS-DDV50

Pulsating Vacuum Desktop Steam Sterilizer TS-DDV35/TS-DDV50

More information about Pulsating Vacuum Desktop Steam Sterilizer,please refer to   http://www.autoclavesale.com/pulsating-vacuum-desktop-steam-sterilizer-lcd-display-built-in-mini-printer-bluestone-ltd.html

How to Calibrate an Autoclave shared by Autoclavesale.com

Medical equipment is commonly sterilized in autoclaves. They are also used in microbiology laboratories. Autoclaves are available in many sizes. The smallest is a stovetop pressure cooker. Like our model PA-BM Portable Autoclave-Bluestone Autoclave. Countertop models are used in dentist’s offices and small medical clinics. Like our model TS-DDZ Dental Autoclave-Bluestone Autoclave. Large solid-state controlled autoclaves are common in laboratories and hospitals. Like Model HA-BC Horizontal Medical Autoclave-Bluestone Autoclave. All autoclaves have temperature and pressure gauges, as well as a timer. Quarterly calibration of the autoclave timer and gauges is important to insure that proper sterilization is occurring.

Portable Autoclave PA-BM_ BLuestone Autoclave

Portable Autoclave PA-BM_ BLuestone Autoclave

Dental Autoclave TS-DDZ - Bluestone Autoclave

Dental Autoclave TS-DDZ – Bluestone Autoclave

Horizontal Autoclave - Bluestone Autoclave

Horizontal Autoclave – Bluestone Autoclave

Timer Calibration

  1. Set the timer on the autoclave for a full cycle. Hold the stopwatch and be prepared to click it.
  2. Turn on the autoclave and the stopwatch simultaneously.
  3. Repeat the process if the time and the stopwatch do not match.
  4. If the autoclave timer differs from the stopwatch time by more than 30 seconds, post an appropriate correction factor directly on the autoclave.
  5. Note the calibration results in a logbook.

Temperature Calibration

  1. Place the maximum registering thermometer near the built-in temperature sensor.
  2. Load and operate the autoclave as usual.
  3. Record the maximum autoclave temperature according to the built-in temperature display.
  4. Let the autoclave cool.
  5. Remove the maximum registering thermometer from the autoclave and record the temperature reading in the logbook.
  6. Record the discrepancy if the maximum temperature of the built-in display is different from the maximum temperature on the registering thermometer.
  7. Post a correction factor on the autoclave control panel if the temperatures were different.

Pressure Calibration

  1. Calibrate the timer and temperature gauges before these steps.
  2. Load and operate the autoclave as usual. When the temperature display shows 121 degrees Celsius, the pressure gauge should show 15 pounds per square inch (15 psi).
  3. Record the discrepancy if there is any.
  4. Mark the correct point for 15 psi on the cover of the gauge and post a correction factor on the autoclave if this is not true.

More information about our product, pls refer our website: http://www.autoclavesale.com

Inquiry about VA-FJ Vertial Steam Sterilizer Medical Autoclave – Bluestone Autoclave

Comment: I’m interested in your product Multi-Function Hospital Sterilization Equipment VA-FJ,I would like some more details: What is the best price you can offer?
I look forward to your reply.

Vertical Autoclave_Bluestone Autoclave

Vertical Autoclave_Bluestone Autoclave

Main Features of VA-FJ Vertical Autoclave Steam Sterilizer from Bluestone Autoclave.

1. Fully stainless steel structure.

2. Indicator light indicates working state.

3. Over temperature & over pressure auto-protection.

4. Double scale indication pressure gauge.

5. Safe protection of water lacking.

6. Automatically shut off with beep reminding after sterilization.

7. Easy to operate, safe and reliable.

8. With two stainless steel sterilizing baskets

More product information, pls refer our website: http://www.autoclavesale.com

Vertical Autoclave manufacture, supplier & Distributor_Bluestone Autoclave

Vertical Autoclave manufacturer, supplier & Distributor_Bluestone Autoclave

Inquiry for 18L Automatic Autoclave

Comment: Good Morning Team,

Please advise the price and availability of the following:
Automatic Autoclave Steam Sterilizer Oven 18L

Automatic Portable Autoclave_Bluestone Autoclave

Automatic Portable Autoclave_Bluestone Autoclave

PA-ND Digital Portable Autoclave Features:

1. Fully stainless steel structure.

2. Hand wheel type of quick-open door structure.

3. Digital display of  working status, touch type key.

4. Automatically shut off with beep reminding after sterilization.

5. Electric heated.

6. Easy to operate, safe and reliable.

More information, pls refer our website: http://www.autoclavesale.com/

portable combo

Portable Autoclave_Bluestone Autoclave